| Type | Application |
| Type W | For use on mobile mining equipment such as continuous miners, drills, cutters, loading machines, AC shuttle cars and pumps |
| Type G | For use on D.C. off-track mining equipment. Especially designed for D.C. shuttle cars, drills, cutting and loading machines |
| Type G-GC | For use on D.C. off-track mining equipment. Especially designed for D.C. shuttle cars, drills, cutting and loading machines |
| Type SHD-GC | Heavy duty portable cable, designed for longwall shearers, continuous miners and mobile equipment |
| Type SHD-PCG | Three shielded power conductors & unshielded control conductors, and a grounding conductor are required. designed for longwall shearers. |
| Type SHD-GCG | Designed for applications such as longwall shearers, continuous miners, loaders, drills, conveyors, pumps, and other mobile equipment |
| Type MP-GC | Connections between units of mine distribution systems for direct burial in wet and dry locations. |
Type SHD-GC Rubber Mining Cable

Voltage: 2kV, 5kV, 8kV
Conductor: flexible bare copper or tinned copper
Insulation: colour-coded 90°C Ethylene Propylene Diene Monomer (EPDM)
Ground Conductor: Two bunched or rope lay stranded bare or tin coated,uninsulated copper
Ground Check Conductor: One stranded bare or tin coated copper with yellow Ethylene Propylene Diene Monomer (EPDM) insulation
Braid Shield: Soft drawn annealed copper braid served over each conductor
Outer Jacket: Flame-retardant, oil & sunlight resistant Chlorinated Polyethylene (CPE) rated temperature 90°C
Options: Other sizes, colours and custom designs available upon request
Ethylene Propylene Rubber (EPR) insulation available upon request
Type SHD-CGC Rubber Mining Cable

Voltage: 2kV, 5kV
Conductor: Flexible tinned copper
Strand Shield: Semi-conducting layer
Insulation: 90°C ethylenepropylene rubber (EPR)
Ground Wires: Flexible tinned copper
Ground Check Conductor: Flexible tinned copper with yellow insulation located in the center of the cable
Insulation Shield: Tinned copper and color-coded nylon braid
Outer Jacket: Reinforced mold-cured thermosetting Chlorinated Polyethylene (CPE) Jacket.
Options: Other sizes, colours and custom designs available upon request
Ethylene Propylene Rubber (EPR) insulation available upon request
Type SHD-PCG Rubber Mining Cable

Voltage: 2kV, 5kV
Conductor: Flexible tinned copper
Strand Shield: Semi-conducting
Insulation: 90°C ethylene propylene rubber (EPR)
Ground 3 Conductors: Flexible tinned copper ethylene polypropylene rubber insulation color coded black, white, red and an overall thermosetting jacket
Ground Conductor: Flexible tinned copper located in the center of the cable
Insulation Shield: Tinned copper and color-coded nylon braid
Outer Jacket: Reinforced mold-cured thermosetting Chlorinated Polyethylene (CPE) Jacket.
Options: Other sizes, colours and custom designs available upon request
Ethylene Propylene Rubber (EPR) insulation available upon request
Type W Round/Flat Mining Cable

Voltage: 2000V
Core: 3,4C,Round,2,4 flat
Conductor: Flexible tinned copper
Tape: Non-conducting
Insulation: 90°C ethylene-propylene rubber(EPR)
Outer sheath: Reinforced mold-cured thermosetting Chlorinated Polyethylene(CPE)
Outer sheath Color: Black, Blue, Green, Orange, Yellow, Red
Type G-GC Rubber Mining Cable

Voltage: 2kV
Conductor: Flexible tinned copper
Ground Wire: Uni-directional lay flexible tinned copper with green covering
Ground Check Conductor: Uni-directional lay flexible tinned copper with yellow insulation
Reinforcement: Synthetic yarnover assembly
Insulation: 90°C ethylenepropylene rubber (EPR)
Outer Jacket: JacketMold-cured thermoset with cable identificationvia permanent marking.
Options: Other sizes, colours and custom designs available upon request
Ethylene Propylene Rubber (EPR) insulation available upon request
Type MP-GC Power Mining Cable

Voltage: 2kV, 5kV, 8kV
Conductor: Copper Class 2
Ground Wire Conductor: Tinned Copper
Ground Check Conductor: 8 AWG 7-wire copper with yellow polypropylene insulation
Strand Shield: Semi-conducting layer
Insulation: 90°C cross-linked polyethylene(XLPE)
Insulation Shield: Semi-conducting layer under copper tape(phase identification provided)
Assembly: Taped core
Outer Jacket: Polyvinyl chloride (PVC), cable identification via permanent surface marking.
TEBAOFLEX Cable Sample Show


| Construction | No. of Strands | Grounding Conductor Size | Ground Check Conductor Size | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity | ||||
| No. of cores×AWG/kcmil | – | AWG/kcmil | AWG/kcmil | inch | mm | inch | mm | inch | mm | lbs/kft | kg/km | A |
| 3×6 | 133 | 10 | 10 | 0.07 | 1.8 | 0.155 | 3.9 | 1.29 | 32.8 | 1130 | 1682 | 93 |
| 3×4 | 259 | 8 | 10 | 0.07 | 1.8 | 0.155 | 3.9 | 1.4 | 35.6 | 1460 | 2173 | 122 |
| 3×3 | 259 | 7 | 10 | 0.07 | 1.8 | 0.17 | 4.3 | 1.51 | 38.3 | 1680 | 2500 | 140 |
| 3×2 | 259 | 6 | 10 | 0.07 | 1.8 | 0.17 | 4.3 | 1.59 | 40.4 | 1990 | 2961 | 159 |
| 3×1 | 259 | 5 | 8 | 0.08 | 2 | 0.19 | 4.8 | 1.76 | 44.7 | 2385 | 3549 | 184 |
| 3×1/0 | 266 | 4 | 8 | 0.08 | 2 | 0.19 | 4.8 | 1.86 | 47.2 | 2765 | 4115 | 211 |
| 3×2/0 | 329 | 3 | 8 | 0.08 | 2 | 0.205 | 5.2 | 2 | 50.8 | 3255 | 4844 | 243 |
| 3×3/0 | 418 | 2 | 8 | 0.08 | 2 | 0.205 | 5.2 | 2.13 | 54.1 | 3890 | 5789 | 279 |
| 3×4/0 | 532 | 1 | 8 | 0.08 | 2 | 0.22 | 5.6 | 2.31 | 58.7 | 4720 | 7024 | 321 |
| 3×250 | 627 | 1/0 | 6 | 0.095 | 2.4 | 0.22 | 5.6 | 2.51 | 63.8 | 5460 | 8125 | 355 |
| 3×300 | 741 | 1/0 | 6 | 0.095 | 2.4 | 0.235 | 6 | 2.68 | 68.1 | 6395 | 9517 | 398 |
| 3×350 | 888 | 2/0 | 6 | 0.095 | 2.4 | 0.235 | 6 | 2.81 | 71.4 | 7280 | 10834 | 435 |
| 3×500 | 1221 | 4/0 | 6 | 0.095 | 2.4 | 0.265 | 6.7 | 3.19 | 81 | 9820 | 14614 | 536 |
| Construction | No. of Strands | Grounding Conductor Size | Ground Check Conductor Size | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Sheath Thickness | Nominal Weight | Ampacity | ||||
| No. of cores×AWG/kcmil | – | AWG/kcmil | AWG/kcmil | inch | mm | inch | mm | inch | mm | lbs/kft | kg/km | A |
| 3×6 | 133 | 10 | 8 | 0.11 | 2.8 | 0.185 | 4.7 | 1.56 | 39.6 | 1560 | 2322 | 93 |
| 3×4 | 259 | 8 | 8 | 0.11 | 2.8 | 0.185 | 4.7 | 1.68 | 42.7 | 1895 | 2820 | 122 |
| 3×2 | 259 | 6 | 8 | 0.11 | 2.8 | 0.205 | 5.2 | 1.87 | 47.5 | 2445 | 3639 | 159 |
| 3×1 | 259 | 5 | 8 | 0.11 | 2.8 | 0.205 | 5.2 | 1.95 | 49.5 | 2800 | 4167 | 184 |
| 3×1/0 | 266 | 4 | 8 | 0.11 | 2.8 | 0.22 | 5.6 | 2.08 | 52.8 | 3230 | 4807 | 211 |
| 3×2/0 | 329 | 3 | 8 | 0.11 | 2.8 | 0.22 | 5.6 | 2.2 | 55.9 | 3800 | 5655 | 243 |
| 3×3/0 | 418 | 2 | 8 | 0.11 | 2.8 | 0.235 | 6 | 2.36 | 59.9 | 4475 | 6660 | 279 |
| 3×4/0 | 532 | 1 | 8 | 0.11 | 2.8 | 0.235 | 6 | 2.5 | 63.5 | 5265 | 7835 | 321 |
| 3×250 | 627 | 1/0 | 6 | 0.12 | 3 | 0.25 | 6.4 | 2.69 | 68.3 | 6105 | 9085 | 355 |
| 3×300 | 741 | 1/0 | 6 | 0.12 | 3 | 0.25 | 6.4 | 2.81 | 71.4 | 6875 | 10231 | 398 |
| 3×350 | 888 | 2/0 | 6 | 0.12 | 3 | 0.265 | 6.7 | 2.95 | 74.9 | 7795 | 11600 | 435 |
| 3×500 | 1221 | 4/0 | 6 | 0.12 | 3 | 0.28 | 7.1 | 3.31 | 84.1 | 10415 | 15499 | 536 |
| Construction | No. of Strands | Grounding Conductor Size | Ground Check Conductor Size | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity | ||||
| No. of cores×AWG/kcmil | – | AWG/kcmil | AWG/kcmil | inch | mm | inch | mm | inch | mm | lbs/kft | kg/km | A |
| 3×6 | 133 | 10 | 10 | 0.07 | 1.8 | 0.155 | 3.9 | 1.29 | 32.8 | 1130 | 1682 | 93 |
| 3×4 | 259 | 8 | 10 | 0.07 | 1.8 | 0.155 | 3.9 | 1.4 | 35.6 | 1460 | 2173 | 122 |
| 3×3 | 259 | 7 | 10 | 0.07 | 1.8 | 0.17 | 4.3 | 1.51 | 38.3 | 1680 | 2500 | 140 |
| 3×2 | 259 | 6 | 10 | 0.07 | 1.8 | 0.17 | 4.3 | 1.59 | 40.4 | 1990 | 2961 | 159 |
| 3×1 | 259 | 5 | 8 | 0.08 | 2 | 0.19 | 4.8 | 1.76 | 44.7 | 2385 | 3549 | 184 |
| 3×1/0 | 266 | 4 | 8 | 0.08 | 2 | 0.19 | 4.8 | 1.86 | 47.2 | 2765 | 4115 | 211 |
| 3×2/0 | 329 | 3 | 8 | 0.08 | 2 | 0.205 | 5.2 | 2 | 50.8 | 3255 | 4844 | 243 |
| 3×3/0 | 418 | 2 | 8 | 0.08 | 2 | 0.205 | 5.2 | 2.13 | 54.1 | 3890 | 5789 | 279 |
| 3×4/0 | 532 | 1 | 8 | 0.08 | 2 | 0.22 | 5.6 | 2.31 | 58.7 | 4720 | 7024 | 321 |
| 3×250 | 627 | 1/0 | 6 | 0.095 | 2.4 | 0.22 | 5.6 | 2.51 | 63.8 | 5460 | 8125 | 355 |
| 3×300 | 741 | 1/0 | 6 | 0.095 | 2.4 | 0.235 | 6 | 2.68 | 68.1 | 6395 | 9517 | 398 |
| 3×350 | 888 | 2/0 | 6 | 0.095 | 2.4 | 0.235 | 6 | 2.81 | 71.4 | 7280 | 10834 | 435 |
| 3×500 | 1221 | 4/0 | 6 | 0.095 | 2.4 | 0.265 | 6.7 | 3.19 | 81 | 9820 | 14614 | 536 |
| Construction | No. of Strands | Nominal Insulation Thickness | Nominal Overall Diameter Height×Width | Nominal Weight | Ampacity | |||
| No. of cores×AWG/kcmil | – | inch | mm | inch | mm | lbs/kft | kg/km | A |
| 4×6 | 133 | 0.06 | 1.5 | 0.67×1.69 | 17.0×42.9 | 895 | 1332 | 72 |
| 4×4 | 259 | 0.06 | 1.5 | 0.75×1.89 | 19.0×48.0 | 1185 | 1764 | 93 |
| 4×2 | 259 | 0.06 | 1.5 | 0.84×2.23 | 20.6×56.6 | 1620 | 2411 | 122 |
| 4×1 | 259 | 0.08 | 2 | 0.97×2.60 | 24.6×66.0 | 2100 | 3125 | 143 |
| 4×1/0 | 259 | 0.08 | 2 | 1.01×2.73 | 25.7×69.3 | 2500 | 3721 | 165 |
| 4×2/0 | 329 | 0.08 | 2 | 1.10×2.96 | 27.9×75.2 | 2900 | 4316 | 192 |
| 4×3/0 | 413 | 0.08 | 2 | 1.18×3.25 | 30.0×82.6 | 3500 | 5209 | 221 |
| 4×4/0 | 532 | 0.08 | 2 | 1.29×3.46 | 32.8×87.9 | 4225 | 6288 | 255 |
| onstruction | No. of Strands | Nominal Insulation Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity | |||
| No. of cores×AWG/kcmil | – | inch | mm | inch | mm | lbs/kft | kg/km | A |
| 3×8 | 133 | 0.06 | 1.5 | 0.91 | 23.1 | 550 | 818 | 59 |
| 3×6 | 133 | 0.06 | 1.5 | 1.01 | 25.7 | 730 | 1086 | 79 |
| 3×4 | 259 | 0.06 | 1.5 | 1.17 | 29.7 | 1020 | 1518 | 104 |
| 3×2 | 259 | 0.06 | 1.5 | 1.34 | 34 | 1430 | 2128 | 138 |
| 3×1 | 259 | 0.08 | 2 | 1.51 | 38.4 | 1800 | 2678 | 161 |
| 3×1/0 | 266 | 0.08 | 2 | 1.65 | 41.9 | 2140 | 3184 | 186 |
| 3×2/0 | 342 | 0.08 | 2 | 1.75 | 44.5 | 2580 | 3839 | 215 |
| 3×3/0 | 418 | 0.08 | 2 | 1.89 | 48 | 2922 | 4347 | 249 |
| 3×4/0 | 532 | 0.08 | 2 | 2.04 | 51.8 | 3800 | 5654 | 287 |
| 3×250 | 741 | 0.095 | 2.4 | 2.39 | 60.7 | 4368 | 6500 | 320 |
| 3×350 | 888 | 0.095 | 2.4 | 2.66 | 67.5 | 5895 | 8772 | 394 |
| 3×500 | 1221 | 0.095 | 2.4 | 2.98 | 75.8 | 7820 | 11638 | 487 |
| Power Conductors | Nominal Outside Dimensions in. | Approx. Weight lbs. per 1,000 ft. | Ampacity* 40°C Ambient Temp |
||
| Size AWG | No. of Wires per Conductor | Insulation Thickness mils | |||
| 8 | 133 | 60 | 0.99 | 670 | 54 |
| 6 | 133 | 60 | 1.1 | 890 | 72 |
| 4 | 259 | 60 | 1.27 | 1250 | 93 |
| 2 | 259 | 60 | 1.48 | 1800 | 122 |
| 1 | 259 | 80 | 1.68 | 2270 | 143 |
| 1/0 | 266 | 80 | 1.79 | 2680 | 165 |
| 2/0 | 323 | 80 | 1.93 | 3200 | 192 |
| 3/0 | 418 | 80 | 2.07 | 3627 | 221 |
| 4/0 | 532 | 80 | 2.26 | 4650 | 255 |
| Construction | No. of Strands | Nominal Insulation Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity | |||
| No. of cores×AWG/kcmil | – | inch | mm | inch | mm | lbs/kft | kg/km | A |
| 5×8 | 133 | 0.06 | 1.5 | 1.07 | 27.2 | 776 | 1154 | 50 |
| 5×6 | 133 | 0.06 | 1.5 | 1.24 | 31.5 | 1024 | 1524 | 68 |
| 5×4 | 259 | 0.06 | 1.5 | 1.36 | 35.2 | 1432 | 2131 | 88 |
| 5×2 | 259 | 0.06 | 1.5 | 1.56 | 39.8 | 2051 | 3052 | 116 |
| 5×1 | 259 | 0.06 | 1.5 | 1.85 | 47.1 | 2665 | 3967 | 136 |
| 5×1/0 | 266 | 0.08 | 2 | 1.98 | 50.4 | 3406 | 5069 | 150 |
| 5×2/0 | 342 | 0.08 | 2 | 2.13 | 54.1 | 3596 | 5351 | 172 |
| 5×3/0 | 418 | 0.08 | 2 | 2.27 | 57.6 | 4728 | 7035 | 200 |
| 5×4/0 | 532 | 0.08 | 2 | 2.46 | 62.6 | 5512 | 8203 | 230 |