TEBAOFlex Cable:BU/RU/BFOU/RFOU/BFOU(i, c, i+c)/RFOU(i, c, i+c) Series: Offshore Marine Power & Instrument Cables (NEK TS 606), These are halogen-free, low-smoke, mud-resistant (SHF2/SHF2 MUD) marine/offshore cables per NEK TS 606, IEC 60092-350/353/360/376, for fixed installation on FPSOs, rigs, platforms, vessels.

Offshore Cable Type Conductor Materials Insulation Screen Layer Amroured Outer Jacket
BU Cable Tinned Copper Class 5 or 2 Mica tape + Halogen Free EPR Non Non low smoke and halogen free
RU Cable EPR Non Non
RFOU Cable Mica tape + Halogen Free EPR TCWB Armored TCWB
BFOU Cable Mica tape + Halogen Free EPR
TFOU Cable XLPE
RFOU(i) Tinned Copper Class 2 EPR individually screened
RFOU(c) EPR collectively screened
RFOU(i+c) EPR individually+collectively screened
BFOU(i) Mica tape + Halogen Free EPR individually screened
BFOU(i+c) Mica tape + Halogen Free EPR individually+collectively screened
BFOU(c) Mica tape + Halogen Free EPR collectively screened

RFOU (i), RFOU (c)/BFOU(i), BFOU(c) Instrument Offshore Cable

250V RFOU(c) Fire Resistant Overall Shield Instrument Offshore Cable

Conductor: Tinned Copper class 2
Insulation: EPR Rubber
Overall screen: Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire.
Armoured: TCWB-Tinned Copper Wire Braid
Outer Jacket: Flame retardant, halogen free and mud resistant thermoset compound.

250V BFOU(i+o) Fire Resistant Individual Shield Instrument Offshore Cable

Conductor: Tinned Copper class 2
Insulation: Mica tape + Halogen Free EPR
OS+IS screen: Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire.
Armoured: TCWB-Tinned Copper Wire Braid
Outer Jacket: Flame retardant, halogen free and mud resistant thermoset compound.

250V BFOU(c) Fire Resistant Overall Shield Instrument Offshore Cable

Conductor: Tinned Copper class 2
Insulation: Mica tape + Halogen Free EPR
Overall screen: Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire.
Armoured: TCWB-Tinned Copper Wire Braid
Outer Jacket: Flame retardant, halogen free and mud resistant thermoset compound.

250V RFOU(i) Fire Resistant Individual Shield Instrument Offshore Cable

Conductor: Tinned Copper class 2
Insulation: EPR Rubber
OS+IS screen: Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire.
Armoured: TCWB-Tinned Copper Wire Braid
Outer Jacket: Flame retardant, halogen free and mud resistant thermoset compound.

BU/BU(i)/BU(i+c)/RU/BU Offshore Marine Cable

BU P110 Mica+HF-EPR/XLPE Insulation Offshore Power Cable

Voltage: 0.6/1(1.2)kV
Conductor: tinned annealed copper (STC), Class 2 or Class 5
Insulation: Mica glass tape(MGT)+XLPE/EPR
Outer sheath: Halogen-free thermoset compound type SHF2.
Outer sheath Color: Black

BU(i) S107 Mica+HF-EPR/XLPE Insulation Offshore Instrument Cable

Voltage:250V
Conductor: tinned annealed copper (STC), Class 2 or Class 5
Insulation: Mica glass tape(MGT)+XLPE/EPR
Twisting and individual screen: Color coded cores twisted pairs / triples, each pairs / triples are
screened by copper backed polyester tape with a tinned copper drain wire and wrapped with polyester tape Pairs / triples are identified by printed numbers.
Outer sheath: Halogen-free thermoset compound type SHF2.
Outer sheath Color: Black

BU(i+c) Mica+HF-EPR/XLPE Insulation Offshore Instrument Cable

Voltage:250V
Conductor: tinned annealed copper (STC), Class 2 or Class 5
Insulation: Mica glass tape(MGT)+XLPE/EPR
Individual & Collective screen: Color coded cores twisted pairs / triples, each pairs / triples are
screened by copper backed polyester tape with a tinned copper drain wire and wrapped with polyester tape.Pairs / triples are identified by printed numbers
Outer sheath: Halogen-free thermoset compound type SHF2.
Outer sheath Color: Black

RU EPR Insulation Offshore Power Cable

Voltage: 0.6/1(1.2)kV
Conductor: tinned annealed copper (STC), Class 2 or Class 5
Insulation: EPR Rubber
Outer sheath: Halogen-free thermoset compound type SHF2.
Outer sheath Color: Black

Low&Medium Voltage RFOU/BFOU/VFD/ Offshore Marine Cable

0.6/1kV(1.8/3kV) RFOU VFD EMC Shield Offshore Marine Cable

Voltage: 0.6/1kV(1.8/3kV
Conductor: Tinned Copper class 2
Insulation: EPR Rubber
Bedding/Inner covering: Halogen free compound
Tape: Copper backed polyester tape ( % 100 coverage )
Braid Armour: Tinned copper wire braid
Outer sheath: Halogen free extruded compoun

0.6/1kV RFOU P1/P8 Fire Resistant Offshore Power Cable

Conductor: Tinned Copper class 2 or 5
Insulation: EPR Rubber
2 conductors: blue + brown
3 conductors: brown + black + grey
4 conductors: brown + black + grey + blue
5 or more conductors: white numbered.
Filling sheath: Flame retardant and halogen free compound
Screen: TCWB-Tinned Copper Wire Braid
Outer sheath: low smoke and halogen free SHF MUD

0.6/1kV BFOU P5/P12 Fire Resistant Offshore Power Cable

Conductor: Tinned Copper class 2 or 5
Insulation: Mica tape + Halogen Free EPR Rubber
2 conductors: blue + brown
3 conductors: brown + black + grey
4 conductors: brown + black + grey + blue
5 or more conductors: white numbered.
Filling sheath: Flame retardant and halogen free compound
Screen: TCWB-Tinned Copper Wire Braid
Outer sheath: low smoke and halogen free SHF MUD.

3.6/6kV~18/30kV RFOU Offshore Marine Cable

Conductor: Tinned Copper class 2 or 5
Insulation: Mica tape + Halogen Free EPR Rubber
2 conductors: blue + brown
3 conductors: brown + black + grey
4 conductors: brown + black + grey + blue
5 or more conductors: white numbered.
Filling sheath: Flame retardant and halogen free compound
Screen: TCWB-Tinned Copper Wire Braid
Outer sheath: low smoke and halogen free SHF MUD.

BFOU P5-P12 Offshore Cable Technology Data

Cross section (mm2) Diameter (mm) Weight (Kg/km) Open Air 45ºC (A) Voltage drop (V/A·km) Max conduc or resistanc at 20ºC (Ohm/Km)
4G4 17,0 460 34 11,24 50,900
4G6 19,1 650 42 7,48 33,900
4G10 21,5 960 57 4,30 19,500
4G16 24,6 1.4 77 2,74 12,400
4G25 29,0 1.9 100 1,76 0,7950
4G35 32,6 2.25 120 1,25 0,5650
4G50 38,9 3.1 145 0,87 0,3930
4G70 41,2 4 180 0,61 0,2770
4G95 48,0 5.05 225 0,46 0,2100
4G120 52,8 6.3 260 0,36 0,1640
4G150 57,3 7.6 300 0,29 0,1320
4G185 62,7 9 340 0,24 0,1080
4G240 69,4 10.4 400 0,18 0,0817
4 x 1,5/4 15,6 385 18 30,30 137,000
4 x 2,5/6 16,5 440 25 18,10 82,100
4 x 4/6 17,3 480 34 11,24 50,900
4 x 6/6 19,2 680 42 7,48 33,900
4 x 10/10 21,6 1 57 4,30 19,500
4 x 16/16 24,6 1.45 77 2,74 12,400
4 x 25/16 29,0 1.95 100 1,76 0,7950
4 x 35/16 32,6 2.5 120 1,25 0,5650
4 x 50/25 38,9 3.3 145 0,87 0,3930
4 x 70/35 41,2 4.2 180 0,61 0,2770
4 x 95/50 48,0 5.3 225 0,46 0,2100
4 x 120/60 52,8 6.6 260 0,36 0,1640
4 x 150/75 57,3 8 300 0,29 0,1320

RFOU P1-P8 Offshore Cable Technology Data

Cross section (mm2) Diameter (mm) Weight (Kg/km) Open Air 45°C (A) Voltage drop (V/Akm) Max conduc or resistanc at 20° C (Ohm/Km)
4G4 16,77 380 34 11,24 50,900
4G6 18,20 590 42 7,48 33,900
4G10 20,67 880 57 4,30 19,500
4G16 23,28 1.25 77 2,74 12,400
4G25 27,96 1.72 100 1,76 0,7950
4G35 30,82 2.2 120 1,25 0,5650
4G50 36,37 2.9 145 0,87 0,3930
4G70 40,28 3.7 180 0,61 0,2770
4G95 46,44 4.65 225 0,46 0,2100
4G120 50,34 5.7 260 0,36 0,1640
4G150 56,24 7 300 0,29 0,1320
4G185 61,70 8.3 340 0,24 0,1080
4G240 68,99 9.75 400 0,18 0,0817
4 x 1,5/4 14,44 300 18 30,30 137,000
4 x 2,5/6 15,52 340 25 18,10 82,100
4 x 4/6 17,05 400 34 11,24 50,900
4 x 6/6 18,37 610 42 7,48 33,900
4 x 10/10 20,67 900 57 4,30 19,500
4 x 16/16 23,28 1.3 77 2,74 12,400
4 x 25/16 27,96 1.765 100 1,76 0,7950
4 x 35/16 30,82 2.3 120 1,25 0,5650
4 x 50/25 36,37 3 145 0,87 0,3930
4 x 70/35 40,28 3.8 180 0,61 0,2770
4 x 95/50 46,44 4.8 225 0,46 0,2100
4 x 120/60 50,34 20.264 260 0,36 0,1640

BFOU(c) Instrument Offshore Cable Technical Data

Cross section (mm2) Diameter (mm) Weight (Kg/km) Open Air 45°C (A) Voltage drop (V/A.km) Max conduc or resistanc at 20°C (Ohm/Km)
1 x 2 x 0,75 11,8 180 17,1 62,5 28,3
2 x 2x 0,75 18,2 375 13,7 62,5 28,3
4 x 2 x 0,75 20,0 460 11,2 62,5 28,3
8 x 2 x 0,75 25,6 600 8,9 62,5 28,3
12 x 2 x 0,75 30,6 730 7,7 62,5 28,3
16 x 2 x 0,75 33,7 1.1 7,0 62,5 28,3
19 x 2 x 0,75 35,4 1.51 6,5 62,5 28,3
24 x 2 x 0,75 41,6 2.05 6,5 62,5 28,3
1 x 2 x 1,5 13,0 230 23,0 32,0 14,5
2 x 2x 1,5 20,4 480 18,4 32,0 14,5
4 x 2 x 1,5 22,1 655 15,0 32,0 14,5
7 x 2 x 1,5 27,5 955 12,4 32,0 14,5
8 x 2 x 1,5 29,0 1.05 12,0 32,0 14,5
12 x 2 x 1,5 33,4 1.25 10,3 32,0 14,5
16 x 2 x 1,5 38,0 1.7 9,4 32,0 14,5
19 x 2 x 1,5 39,8 2.15 9,0 32,0 14,5
24 x 2 x 1,5 46,9 2.7 8,5 32,0 14,5

The Marine&Offshore Cables Application Scenarios

Ports

Offshore Oil and Gas Platforms

Marine Vessels and Shipbuilding Projects

Offshore Renewable Energy Facilities

Control and Instrumentation Systems

Service and Maintenance Circuits

Offshore Drill Platforms