450/750V H07RN-F EPR/PCP Rubber Cable

  • Voltage: 450V/750V
  • Conductor: Class 5 Flexible Stranded Copper
  • Cores: 1~24cores
  • Insulated: EPR (Ethylene Polypropylene Rubber)
  • Outer Sheath: PCP (Polypropylene)
  • Temperature Rating: -30oC to +60oC/ Insulation tested to +90oC
  • Core Identification

300/500V H05RN-F EPR/PCP Rubber Cable

  • Voltage: 300V/500V
  • Conductor: Class 5 Flexible Stranded Copper
  • Cores: 2~4Cores
  • Insulation: EPR (Ethylene Polypropylene Rubber) EI4
  • Outer Sheath: PCP (Polypropylene) EM2
  • Temperature Rating: -40°C to +60°C/ Insulation tested to +90°C
  • Core Identification

450/750V TGSH, TGSH-J, TGSH-O HEPR/SIR Rubber Cable

TGSH, TGSH-J, TGSH-O
  • Voltage: 450V/700V
  • Conductor: copper,tinned copper class 5
  • Cores: 1~4 Cores
  • Insulation: Ozone, weather, heat and water resistant insulation compound, base SIR
  • Outer Sheath: Special compound, base HEPR, black
  • Core Identification:

450/750V TGSH2G, TGSH2G-J, TGSH2G-J SIR/SIR Rubber Cable

  • Voltage: 450V/700V
  • Conductor: copper, tinned copper class 5
  • Cores: 1~4 Cores
  • Insulation: Ozone, weather, heat and water resistant insulation compound, base SIR
  • Outer Sheath: Ozone, weather, heat and water resistant insulation compound, base SIR
  • Core Identification:

Application of Difference Rubber Cables

The H07RN-F Heavy-duty flexible trailing rubber cables are designed to provide high flexibility and have the capacity to withstand weather, oil/grease, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.

The H05RN-F Cable use in domestic premises, kitchens, offices and industrial equipment where the cables are subjected to low mechanical stress. Suitable for dry, damp and wet installations, including temporary outdoor power. Supply of electricity and communications in buildings and other civil engineering works with the objective of limiting the generation and spread of fire.

The TGSH, TGSH2G cables are intended for connection of electrical equipment in hot water and for medium mechanical stresses.These cables are also suitable for use in industrial water, cooling water, surface water, rainwater, groundwater and seawater (salt water) up to 2000 m water depth. When corrosive water is involved, or water of some other special compositions must be investigated in each individual case.These cables can be used indoors, outdoors, in industrial and agricultural plant, but not in explosion-hazard areas.For protected, fixed installation within equipment, pipes or wells, as well as for rotor connections.