Application of CABLE AUTOSOPORTADO PARA ELEVADORES 3×8+3×16 AWG

TEBAOFLEX CABLE For mine elevators.The PVC outer cover provides excellent abrasion resistance.In the event of a fire, the cable’s outer sheath is non-flammable and self-extinguishing, exceeding the IEC 60332-1-2 standard: pre-mixed flame of 1 kW.The cable’s outer sheath is UV-resistant, exceeding ASTM G-155 standards.

CABLE AUTOSOPORTADO PARA ELEVADORES 3×8+3×16 AWG Construction

Phase conductor: Three conductors of 8 AWG, made of electrolytic copper with a minimum purity of

99.99%, flexible K-class wiring.

Phase Insulator:: Polyvinyl Chloride (PVC) in black, blue, and brown.
Conductor control:: Three conductors of 16 AWG electrolytic copper with a minimum purity of 99.99%, flexible K-class wiring.
Control insulation: Polyvinyl chloride (PVC) in black, blue, and brown.
Control Meeting: Three insulated conductors of 16 AWG
Total Meeting: 3 insulated phase conductors of 8 AWG plus the previously formed set.
Inner cover: Extruded layer with polyvinyl chloride (PVC)
Exterior Cover: Diamond-shaped   extruded    layer   with   polyvinyl   chloride    (PVC)   flame-retardant, abrasion-resistant, and UV-resistant. Includes 2 flexible galvanized steel cables arranged parallel on the sides.
Color: Yellow exterior cover

CABLE AUTOSOPORTADO PARA ELEVADORES Perú

CABLE AUTOSOPORTADO PARA ELEVADORES 3×8+3×16 AWG Technical data

Brand: TEBAOFLEX CABLE
Type designation: 0.6/1 (1.2) kV Self-supporting cable for elevators, 3×8+3×16 AWG
Standard: IEC 60228:IEC 60502-1 2010:IEC 60332-1-2:UL 2556:ICEA S-95-658:

NTP-IEC 60228-2010:NTP-IEC 60502-1 2010:NTP-IEC 60811-1-1:

Normal Voltage: Uo / U (Um) = 0.6/1 (1.2) kV
Dielectric  strength: Approximately  3.5  kV;
Dielectric strength time: 5 minutes
Max. operating temperature of the conductor : 80°C
Emergency overload maximum: 100°C
Maximum conductor temperature in short circuit: 160°C
Min Bending Radius Current Carrying: Acc. to DIN VDE 0298 part 3
Galvanized steel flexible cable: 3/16″ diameter
Minimum breaking load: 1,300 kg·ft

Cable para alimentación de puente grúa yo elevadores mineros

CABLE AUTOSOPORTADO PARA ELEVADORES 3×8+3×16 AWG International Standard

Construction: DIN VDE 0250-813
General Requirements: DIN VDE 0250-1
Guide Use: DIN VDE 0298-3
Electrical Tests: DIN VDE 0472-501, 503, 508
Non-Electrical Tests: DIN VDE 0472-401. 402,602,303, 615
Under Fire Condition Tests: DIN VDE 0472-803, 804
Flame Retardant: VDE 0482-332-1-2,DIN EN 60332-1-2,IEC 60332-1
Oil Resistant: HD/EN/IEC 60811-2-1.,DIN VDE0473-811-2-1
Water resistance: EN 50525-2-21 (HD 22.16)
Weather resistance: Unrestricted use outdoors and indoors, resistant to ozone, UV and moisture

Cable information 0.6/1 (1.2) kV Self-supporting cable for elevators, 3×8+3×16 AWG

Product code Number of cores x cross section AWG Number of Conductor Wires Insulation thickness

 (mm)

Outer diameter Weight (ca.) Length/drum Drum Qty Gross Weight/Drum Package
8 AWG 16AWG 8 AWG 16 AWG mm kg/km M/Drum NO. Kg/Drum
TEBAOFLEX0213 3×8+3×16 168 26 1.0 0.8 25 x 34 1220 1000 1 1325