Aircraft 400Hz cables manufactured by TEBAOFLEX Cable, China, Below is a selection of our cables and their specifications. If you do not see the cable you are looking for, please do not hesitate to contact us. Drop us a line about your project and cable needs and we will be in touch!
Contact Us By E-Mail: info@tebaoflexcable.com

400 FRNC-deltaflex Open twisted symmetrical Airport 400Hz cables(3×70+10×2,5+8×1)

Power conductors: Tinned fine copper strandsacc. to VDE 0295, IEC 60228 class 6
Size: Split concentric Halogen free Airport 400 Hz Cable 3×50+10×2,5+8×1
Split concentric Halogen free Airport 400 Hz Cable 3×70+10×2,5+8×1
Insulation: Cross-linked Ethylene-Propylene-Rubber (EPR)
Control cores: 3 × (8 × 1 mm²) tinned fine copper strandsacc. to VDE 0295, IEC 60228 class 5
Insulation: Polyolefin copolymer cross-linked
Colour: White with numbers printed in black
Control cores and neutral conductor: Concentric stranding arround the phase conductors
Outer sheath: Abrasion resistant polyurethane (PUR), 2 layers with abrasion indicators
Colour of sheath: Yellow
Abrasion warning: Orange
400 FRNC-flex 4 Leiter Aicraft 400Hz Ground Power with Control Cores (SII 4x1x95 + 4×1 ft, SII 4x1x70 + 4×1 ft )

-Power conductors: Bare fine copper strands, according to VDE 0295, IEC 60228,50 mm² class 5, 70 mm² class 6
-Size: SII 4x1x70 + 4×1 ft, SII 4x1x95 + 4×1 ft
Insulation: Cross-linked Ethylene-Propylene-Rubber (EPR)
-Control cores: 4 × 1 mm², tinned fine copper strands, VDE 0295, IEC 60228, class 6
Insulation: Polyolefin copolymer double insulation
Colour: Grey with numbers printed in black
-Outer sheath: Abrasion resistant polyurethane (PUR)
-Sheath colour: Yellow
FRNC-flex 1 Leiter 28 VDC Aicraft 400Hz Cable (SII 35, 50,70, 95,120) x 4×1 ft

-Power conductors: Tinned fine copper strands, VDE 0295, IEC 60228, class 6
-Size: SII 35 + 4×1 ft
SII 50 + 4×1 ft
SII 70 + 4×1 ft
SII 95 + 4×1 FT
SII 120 + 4×1 FT
-Insulation: Cross-linked Ethylene-Propylene-Rubber (EPR)
-Control cores: 4 × 1 mm², tinned fine copper strands, VDE 0295, IEC 60228, class 6
Insulation: Polyolefin copolymer double insulation
-Colour: Grey with numbers printed in black
-Outer sheath: Abrasion resistant polyurethane (PUR)
-Sheath colour: Yellow, Abrasion warning: Orange
400 FRNC-quadroflex Twisted flexible power cables

-Power conductors: Bare fine copper strands, according to VDE 0295, IEC 60228,50 mm² class 5, 70 mm² class 6
Insulation: Cross-linked Ethylene-Propylene-Rubber (EPR)
-Control cores: 8 × 1 mm², bare fine copper strands, according to VDE 0295, IEC 60228, class 5
Insulation: Polyolefin copolymer
Colour: White with numbers printed in black
-Outer sheath: Abrasion resistant polyurethane (PUR)
-Sheath colour: Orange
400 FRNC-drumflex-LE Flexible power cables with shielded control cores

-Power conductors: Bare fine copper strands, according to VDE 0295, IEC 60228,50 mm² class 5, 70 mm² class 6
Insulation: Cross-linked Ethylene-Propylene-Rubber (EPR)
-Control cores: 8 × 1 mm², bare fine copper strands, according to VDE 0295, IEC 60228, class 5
Insulation: Polyolefin copolymer
Colour: White with numbers printed in black
Colour: White with numbers printed in black, No 1-18…24
-Outer sheath: Abrasion resistant polyurethan (PUR) reinforced with fibres
-Sheath colour: Yellow
-Abrasion warning: Orange
400 FRNC-drive-V Flexible jet cables with control cores

Power conductors: Tinned fine copper strands acc. to VDE 0295, IEC 60228 class 6
Core Insulation: Cross-linked Ethylene-Propylene-Rubber (EPR)
Colour: Black with white numbering 1–3, blue neutral conductor
-Control cores: Tinned fine copper strands, VDE 0295, IEC 60228, class 5
Core insulation: Polyolefin copolymer, X-linked,
Colour: White with numbers printed in black, No 1-18…24
-Outer sheath: Abrasion resistant polyurethan (PUR) reinforced with fibres
-Sheath colour: Yellow
-Abrasion warning: Orange
400 FRNC-smartflex-V2 Flexible power cables with neutral conductor

Conductors: Tinned fine copper strands acc. to VDE 0295, IEC 60228 class 6
Core Insulation: Power cores cross-linked Ethylene-Propylene Rubber (EPR); neutral conductor polyolefin copolymer, Beta X-linked
Colour: Black with white numbering 1–3, blue neutral conductor
Control cores: Tinned fine copper strands, VDE 0295, IEC 60228, class 5
Core insulation: Polyolefin copolymer, X-linked,
Colour: White with numbers printed in black, No 1-18…24
Outer sheath: Abrasion resistant polyurethan (PUR) reinforced with fibres
Sheath colour: Yellow
Abrasion warning: Orange
400 groundflex Flexible single core grounding cable

Conductors: Tinned fine copper strands acc. to VDE 0295, IEC 60228 class 6
Core Insulation: Power cores cross-linked Ethylene-Propylene Rubber (EPR)
Colour: orange
Outer sheath: Abrasion resistant polyurethan (PUR)
Sheath colour: green-yellow
| Construction | Outer Ø) | Outer Ø single conductor | Weight | Bending radius static installation | Bending radius mobile |
| n×mm2 | mm | mm | kg/km | mm | mm |
| 4×1×50+(8×1) | 39.6 | 16 | 2587 | >126 | >170 |
| 4×1×70+(8×1) | 44.3 | 18.3 | 3286 | >132 | >176 |
| 400 FRNC-flex 4-Leite | |||||
| 4×(1×50+4×1) | 44 | 18.2 | 2660 | >176 | >220 |
| 4×(1×70+4×1) | 49.9 | 20.2 | 3590 | >205 | >256 |
| 400 FRNC-flex 1-Leite | |||||
| 1×120+(4×1) | 23.3 | – | 1340 | >148 | >197 |
| 400 FRNC-drumflex-LE | |||||
| 1×35+6×35+6×(4×1) C | 45.5 | — | 3695 | >161 | >242 |
| FRNC-smartflex-V2 | ||||
| Construction) | Outer Ø | Weight | Bending radius static installation | Bending radius mobile |
| n×mm2 | mm | kg/km | mm | mm |
| 1×25+6×25+6×(3×1) | 38.2 | 2600 | >152 | >228 |
| 1×35+6×35+6×(4×1) | 42.8 | 3360 | >170 | >255 |
| 400 FRNC-drive-V | ||||
| Construction) | Outer Ø | Weight | Bending radius static installation | Bending radius mobile |
| n×mm2 | mm | kg/km | mm | mm |
| 3 × 50 + 3×10 + 6× (4×1) | 40.3 | 2830 | >161 | >242 |
| 3 × 70 + 3×20 + 6 × (4×1) | 12.9 | 3455 | >172 | >258 |